CARIS HIPS and SIPS : HIPS and SIPS : Workflow in HIPS and SIPS : Processing Workflow for Water Column Data : WCI Workflow - Subset Editor
 

WCI Workflow - Subset Editor

 
WCI Data in Subset Editor
Display options
Survey lines

1. Open a project to which the water column data will be added.

2. Load selected data in Subset Editor (2D and 3D views)

3. Filter by intensity ranges determined in Swath Editor

4. Query/ Reject /Accept bathymetry data

5. Designate critical soundings

6. Select and add points to additional bathymetry layers.

Working with Additional Bathymetry Layers

1. Toggle views between WCI, project bathymetry and additional bathymetry layers.

2. Compute TPU for additional bathymetry.

3. If required, undo all processing of Additional Bathymetry, with Restart Cleaning command.

4. Regenerate additional bathymetry layers if project data has new corrections and new merge applied.

5. Add additional bathymetry to surfaces.

Adding Additional Bathymetry to a surface will apply outdated or updated status to the surface, depending on the Automatic Surface Update setting.

When Automatic Surface Update is off, saving edits in Subset Editor no longer reports warning messages that the surfaces are out-of-date and require recompute.