HIPS and SIPS Module : Workflow in HIPS and SIPS : Side Scan Editor workflow : Streamlined workflow
 

Streamlined workflow

1. Open converted data in HIPS and SIPS.

2. Open one line in Side Scan Editor for investigation and to determine appropriate correction settings.

3. Correct altitude if necessary. Automatically digitize altitude.

4. Apply an appropriate TVG and Gain correction using the controls in the Properties window. (Display will update dynamically as values are changed.)

5. Create a beam pattern file and load it using the controls in the Properties window.

6. When satisfied with the quality of the image, close Side Scan Editor and save the settings.

7. Create a mosaic from selected lines (using the Tools > Mosaics > New command.

Advanced settings can be drawn from the settings configured in Side Scan Editor properties.

8. Create and edit contacts.