Description
The ImportMultipleDetectionsToHIPS process will import additional bottom detections per beam for use in HIPS processes.
Update
One or more HIPS track lines.
Outputs
Updated HIPS track lines.
Command Line Syntax
carisbatch --run ProcessKey [Options] Inputs Outputs
Options
The following table describes the parameters available for this process.
Parameter |
| |||
Long | Short | Description | Can Repeat | Notes
|
--reject-type | Reject detections of the numbered type. For Kongsberg systems, setting these flags will override the acquisition settings. Type 6 and 7 apply to Kongsberg systems only. • TYPE1: Type 1 • TYPE2: Type 2 • TYPE3: Type 3 • TYPE4: Type 4 • TYPE5: Type 5 • TYPE6: Type 6 • TYPE7: Type 7 | FALSE | ||
Example
To use this command, refer to the following example.
Example | ||
Objective | To import additional bottom detections per beam for use in HIPS processes. | |
Description | Command Line Syntax | |
Detections of Type 4 will be rejected. | --reject-type TYPE4 | |
Detections of Type 5 will be rejected. | --reject-type TYPE5 | |
The input (line data) file is named input.hips and is located at C:\temp\input\. The HIPS file URI filters for the vessel named “sample” and the day 2000-001. | C:\temp\input\input.hips?Vessel=sample;Day=2000-001 | |
Command Line |
| |
Outcome | The line data is updated with the tide values. | |
Extra Notes | N/A | |