HIPS and SIPS Module : HIPS and SIPS Commands L to Z : Set Status Flags
 

Set Status Flags

Within HIPS and SIPS data structure each sensor data value has a series of status flags. Each profile in depth and side scan formats, and each survey line also has status flags.

The status flag settings are determined during data cleaning and processing. They can be used to control which data is used in the generation of new surfaces, tiles, and selected soundings, etc.

Related commands:

Status Flags and Values

Procedure: Accept/Reject

1. From the Edit >Status Flag menu or Status Edit toolbar, select either Port, Starboard or Both to apply edits to.

2. Right-click and select Query from the pop-up menu to view the selected data in the Selection window.

3. Select the Reject command to reject all the selected data. This command is also available from the pop-up menus in the View and Selection windows

 

Menu

Edit > Status Flag > Reject/

Tool

On Status Edit toolbar

The status of the ping or range of pings is set to Rejected and are excluded from further processing in SIPS.

To view Rejected data use the Display Filter function. See Display filter for information.

Accept

Rejected data is not deleted and can be reverted using the Accept command. To make rejected data available for further processing:

1. Select the rejected pings.

2. Apply the Accept command.

 

Menu

Edit > Status Flag > Accept

Tool

Pop-up

Accept

Previously rejected data is now flagged as accepted and is visible again in the Side Scan View.