CARIS HPD : Command Reference : V : Validation : S-58 Edition 7.0 ENC Validation Workflow : Step 2: S-58 Grouped Checks
 
Step 2: S-58 Grouped Checks

S-58 grouped checks are not available in CARIS HPD Paper Chart Editor and CARIS Paper Chart Composer.

Once the ENC has correct chain-node topology, check features and attributes, then spatial geometry, then other aspects of S-58 using the grouped S-58 Edition 7.0 QC Tests, All these tests should be run on all data in the main product data layer.

S-58 features and attributes

Check S-58 features and attributes:

1. Run the S-58 Features and Attributes QC Test.

This test automatically runs the following set of QC Tests:

Duplicate Objects using the Duplicate Geometry, Feature Acronym and Feature Attributes Only option. This is for all features except soundings.

Duplicate Objects using the Duplicate Geometry Only option.This tests the geometry of soundings.

Prohibited Objects using no options

Prohibited Primitives

Invalid Attributes using the Allow Unicode characters in National Attributes option.

Mandatory Attributes

2. Review the validation report.

If any issues are reported, correct them, then repeat this test until no issues remain.

S-58 geometry

Check S-58 geometry:

1. Run the S-58 Geometry QC Test.

This test automatically runs the following set of QC Tests:

Prohibited Objects using the Check for edges with coordinates that are too close option.

Invalid Geometry using no options.

Overlapping Edges

Redundant Edges, Points and Soundings using no options.

Intersecting Edges using no options.

Edges with Redundant Vertices

Edges to Merge

Lines To Merge

Points Inside Areas using no options.

Lines Bordering Areas using the Ignore Administrative attributes (RECDAT, RECIND, SORDAT and SORIND) and SCAMIN when comparing objects option.

2. Review the validation report.

If any issues are reported, correct them, then repeat this test until no issues remain.

Other S-58 aspects

Check other S-58 aspects:

1. Run all other S-58 related QC Tests

These are all tests that start with ‘S-58’ except S-58 Critical Error, Errors or Warnings.

2. Run these QC Tests individually or together:

S-58 Soundings

S-58 Collection Features

S-58 Parent Child Relationships

S-58 Orient, Usage, Mask Flags

S-58 Depth Areas and Depth Contours

S-58 Data Coverage

S-58 Meta Object Coverage

S-58 Group 1 Area Coverage

None of these tests have Options settings:

3. Review the validation report.

If any issues are reported, correct them, then repeat these tests until no issues remain.

If you made any corrections to the dataset, repeat all tests in steps 1 and 2 to ensure that no issues remain.